The automatic sequence of a specification written as IEC 61131-3 Structured Text, to the house coding guideline, using the house library unchanged.

A step chain has to follow the specification step by step, the house rules line by line, and the released I/O list exactly. That is where general-purpose models write code that reads well and does not fit the plant.
Capability
Code
Typed by
PLC programmer
Works with
Functional specification (PDF), PLC coding guideline, House library block FB_Cylinder, Released I/O list
Delivers
PRG_Sequence.st, one POU

The request, as typed

Write PRG_Sequence for LRU-40 in Structured Text: the automatic step chain of FS §5, per plc/PLC-coding-guideline.md, using the FB_Cylinder block from plc/library unchanged. Addresses only from released/LRU40_IO-list_revA.xlsx. Save it in outputs/plc/.
seib Cowork, the program: The header, the commands the chain sets, and the library instances, as written.
The header, the commands the chain sets, and the library instances, as written.Open full size

How the run worked.

seib-1 never touches a file or a system. It writes each next step as a tool call; seib Cowork checks it, runs it, and sends the result back. Anything that writes waits for a person.

  1. In

    What it read

    • Functional specification (PDF)
    • PLC coding guideline
    • House library block FB_Cylinder
    • Released I/O list
  2. Model

    seib-1

    • Plans the task
    • Writes each next step as a tool call
    • Reads every result before the next
  3. Desktop

    seib Cowork runs

    • read_file: specification pages, guideline, library block, I/O list
    • write_file
  4. Person

    Approves

    • Asked before writing the file, shown line by line.
    • Out: PRG_Sequence.st, one POU

Inside the run.

Turns from this run, word for word: the tool calls seib-1 wrote, in the format seib Cowork reads, and what came back. Shortened only where an ellipsis says so.

  1. 01seib-1Tool call
    <tool_call>
    {"tool": "read_file", "input": {"path": "spec/FS-LRU40_Functional-Specification_RevB.pdf", "pages": "4-6"}}
    </tool_call>
  2. 02CoworkTool result
    spec/FS-LRU40_Functional-Specification_RevB.pdf, pages 4-6 of 8 (15.8 KB), are attached to this message. Cite page numbers of the original document.
  3. 03seib-1Tool call, shortened
    <tool_call>
    {"tool": "write_file", "input": {"path": "outputs/plc/PRG_Sequence.st", "content": "…
    CASE eStep OF
    
        S0_HOME:
            (* S0: home position - lift down, turntable at 0 deg, conveyors stopped. *)
            (* No timeout: the home position is the machine's rest state; a cylinder *)
            (* that cannot reach it is reported by its own FB_Cylinder timeout. *)
            xCmdLiftDown := TRUE;
            xCmdRot0     := TRUE;
            xCmdM10Run   := FALSE;
            xCmdM40Run   := FALSE;
            IF fbY20.xAtHome AND fbY30.xAtHome THEN
                eStep := S1_INFEED;
            END_IF;
    
        S1_INFEED:
            (* S1: infeed - M10 runs, wait for a tray at B11. *)
            xCmdM10Run   := TRUE;
            …"}}
    </tool_call>
  4. 04CoworkAfter approval
    Created outputs/plc/PRG_Sequence.st (217 lines).

What it did.

It stopped to ask before writing the file, shown line by line.

  1. 1

    Read the step table and alarms in the specification, the coding guideline, the FB_Cylinder block and the released I/O list.

  2. 2

    Wrote one CASE on an enum step variable, S0_HOME to S8_HAND_OVER, setting commands only, with outputs left to PRG_Outputs as the guideline requires.

  3. 3

    Gave every waiting step a timeout from one step timer, with the limits as named constants and the specification's alarm numbers.

  4. 4

    Showed the 217-line file for approval before writing it.

What came back.

PRG_Sequence.st follows specification §5 and the guideline: FB_Cylinder instances fbY20 and fbY30 used unchanged; a halt on timeout that waits for reset and start; and S0 without a timeout, with the comment the guideline asks for. It flagged that step S4 depends on sensor -B24, which exists on no drawing, rather than inventing an address for it.

Every screen is a capture of seib Cowork 0.2.5 running the request shown on seib-1, the real model, with no step scripted. The systems and documents are seib’s test environment: two fictional companies, Nordhafen Components (a machine-building plant) and the Brennholt Group (a six-company group), with generated data. Where a folder carries project instructions, such as the names of a database’s tables, the run used them, as a customer’s would. Names, keys and file paths of the machine that ran it are masked; nothing else on a screen is changed. No customer data appears.

Request pilot access.

Not a waitlist. Tell us the problem and we’ll tell you honestly whether seib is ready for it.

  1. 1A person reads your request and replies within a few business days.
  2. 2A short call about the line, the toolchain and what's slow today.
  3. 3A Cowork pilot starts with one team, read-only connectors and two or three knowledge bases.
Pilot request, confidential0 of 5 complete
Interested in